Objective. Students will identify a compressor, air dryer, filter-regulator-lubricator (FRL) unit, directional control valves (2/2, 3/2, 5/2, 5/3), flow control valves, and single- and double-acting cylinders by name and function, and read ISO 1219 schematic symbols for each.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Pneumatic systems use compressed air to create controlled mechanical motion. In manufacturing and marine automation, pneumatics move parts, clamp workpieces, actuate valves, and assist robots. Before you can build, troubleshoot, or maintain a pneumatic circuit, you must recognize every major component by sight, know its function, and read its ISO 1219 schematic symbol.
Compressed air carries stored energy that can cause serious injury. Always treat a pneumatic line as energized until you have verified it is not. Follow OSHA 29 CFR 1910.147 (lockout/tagout) when working on machinery: isolate the air supply, depressurize the system, and verify zero energy before opening fittings or removing components. Wear safety glasses at minimum; escaping air can propel debris or cause eye injury. Respect OSHA 1910.212 machine-guarding rules — cylinder rods can extend rapidly and strike a hand. Never direct compressed air at skin or toward another person.
The compressor is the power source of a pneumatic system. It converts mechanical energy (usually from an electric motor) into potential energy stored as pressurized air in a receiver tank. Industrial shops typically supply air at 80–120 psi (approximately 550–825 kPa). The compressor itself is upstream of every other component and is controlled separately. In your schematic, the compressor is shown as a circle with a triangle pointing inward toward the circle, representing the inlet, mounted on a rectangle representing the tank.
Moisture in compressed air corrodes valves, washes out lubricants, and damages cylinders. A refrigerated or desiccant air dryer removes water vapor downstream of the compressor and receiver. In schematics it is represented by a box with a zigzag or cooling element symbol inside. Many facilities combine drying with filtration.
The FRL is a three-stage service unit mounted near the machine, always in the order Filter → Regulator → Lubricator.
In ISO 1219, each section has its own symbol; the three are drawn in series with connecting lines.
DCVs route compressed air to and from actuators. They are named by positions/ports: a 2/2 valve has 2 ports and 2 positions (on/off); a 3/2 valve has 3 ports and 2 positions (used to extend or retract a single-acting cylinder); a 5/2 valve has 5 ports and 2 positions (the standard valve for a double-acting cylinder); a 5/3 valve has 5 ports and 3 positions (center position can be exhaust, pressure, or blocked — you must identify which type).
ISO 1219 DCV symbols use boxes (one box per position), arrows inside showing flow paths, blocked-T shapes for closed ports, and external actuation symbols:
Always read the symbol in its rest (de-energized) position, which is the box nearest the actuation symbol that acts last (spring or pilot return side).
A flow control valve (also called a needle valve with check) meters the air speed by restricting flow in one direction while allowing free flow in the other through an internal check valve. Meter-out restricts exhaust air leaving the cylinder (preferred for most cylinder applications because it provides smooth, controlled motion). Meter-in restricts supply air entering the cylinder. The ISO 1219 symbol shows a variable restrictor (arrow through a circle) in parallel with a check valve (triangle pointing in the free-flow direction).
A single-acting cylinder (SAC) has one port; compressed air extends the rod and a spring returns it. It is used where force is needed in only one direction. The ISO 1219 symbol shows a rectangle (barrel) with a rod, one port arrow, and a spring symbol inside.
A double-acting cylinder (DAC) has two ports — one at each end of the barrel. Compressed air can both extend and retract the rod under power, giving force in both directions. Most industrial cylinders are double-acting. The ISO 1219 symbol shows a rectangle with a rod and two port arrows, no spring.
Cylinder force is calculated as: Force = Pressure × Area (where area = π × bore² ÷ 4). This formula tells you how much push or pull a cylinder can produce at a given supply pressure.
Trace air flow from left to right (supply to actuator): Wall supply → Compressor/receiver → Air dryer → FRL (filter, regulate, lubricate) → DCV → Flow control valves → Cylinder. Each connection is a line; each component is its ISO 1219 symbol. Annotate port labels: P = pressure supply, A and B = cylinder ports, R or EA/EB = exhaust ports.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →