Objective. Students will design, build, commission, and fully document a multi-actuator electro-pneumatic or electro-hydraulic circuit that meets a written functional specification, demonstrating competence across all course topics.
This lesson, its worked examples and its practice questions has not yet been verified by a licensed engineer or certified journey-level tradesperson or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
This capstone lab brings together every skill you have developed in this course. You will design a multi-actuator electro-pneumatic or electro-hydraulic circuit from a written functional specification, build and commission it on a trainer, and produce professional documentation. Industry technicians follow exactly this workflow when installing or retrofitting automated machinery.
Start by reading the functional specification carefully. Identify every actuator, every sensor, every interlock condition, and the required sequence. A typical spec might read: Cylinder A clamps the workpiece; only after Cylinder A is fully extended and confirmed by a limit switch may Cylinder B advance to drill; both cylinders retract on cycle complete or on E-stop.
Draw a complete circuit schematic using ISO 1219 symbols. ISO 1219 is the international standard for fluid power diagrams; using it means any trained technician anywhere can read your drawing. Show every component: compressor/power unit, pressure relief valve, filter-regulator-lubricator (FRL) unit, directional control valves with solenoid and spring symbols, flow controls, actuators, limit switches, and pressure gauges. Number each line and label each component with a tag that matches your bill of materials.
Prepare a component list that includes manufacturer part numbers and the pressure and flow ratings of each item. Verify that all components are rated above the system's maximum operating pressure with appropriate safety margin.
Complete a pre-build safety review before touching any hardware. Identify every lockout/tagout (LOTO) point — the compressed-air supply isolation valve and, for hydraulic systems, the hydraulic power unit — and document them per OSHA 29 CFR 1910.147 (Control of Hazardous Energy). Select PPE: safety glasses rated for fluid-power work at minimum; face shield if working above the trainer on pressurized fittings; steel-toed footwear. Note that NFPA 70E governs the electrical wiring and PLC panel work — verify the panel is de-energized before wiring, use appropriate PPE for the voltage level, and follow energized-work procedures when testing live circuits. Machine guarding requirements (OSHA 1910.212) apply to any moving actuator; confirm guards or barrier distance are in place before cycling.
Install components on the trainer in the order shown on your schematic. Route tubing or hose neatly and use proper fittings torqued to the trainer manufacturer's specification — most push-to-connect pneumatic fittings are hand-tightened only. Route electrical wiring away from fluid lines to reduce contamination risk.
Wire the PLC I/O per your I/O list: each limit switch to a discrete input, each solenoid to a discrete output (through any relay or solid-state driver the trainer requires). Program the sequence in the PLC using IEC 61131-3 ladder diagram or sequential function chart. Use interlocks — a rung enabling Cylinder B's advance output must include a contact from the Cylinder A extended limit-switch input, ensuring the sequence cannot skip a step.
Program the E-stop circuit so that activating the E-stop button immediately de-energizes all solenoid outputs and exhausts pressure through the valves. E-stop logic must be fail-safe: use a normally-closed (NC) E-stop contact wired in series with the output coils, not controlled by software alone. For pneumatic systems, a dump valve or the DCV spring-return position will vent the actuators when solenoids drop out.
Before applying power or pressure: perform LOTO verification, confirm all fittings are seated, and have a classmate or instructor check your wiring. Apply pressure gradually while watching the pressure gauge — do not exceed the rated system pressure. Test each step of the sequence manually before running the automatic cycle. Demonstrate full automatic operation and a deliberate E-stop activation to your instructor.
Professional technicians maintain complete documentation; it is required for maintenance, safety audits, and troubleshooting by the next technician on shift. Your lab report must include:
The oral debrief is ten minutes. Be ready to explain one design decision — for example, why you sized the flow control orifice the way you did — and describe one specific troubleshooting step you took during commissioning. Speak in technical terms; use component tag numbers from your schematic.
Your system passes when: the circuit meets every criterion in the written specification; the E-stop functions correctly every time it is tested; the lab report contains all required sections; and you answer the oral debrief questions demonstrating real understanding. The scoring threshold is full specification compliance plus 80% of the report rubric points.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →