Objective. Students will describe the function of the compressor, governor, air dryer, and wet/dry tanks, and demonstrate how to drain tanks and test governor cut-in and cut-out pressures.
This lesson, its worked examples and its practice questions has not yet been verified by a certified examiner or master technician in the trade or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Heavy trucks equipped with air brakes depend on a continuous, clean, and dry supply of compressed air. Four major components work together to build, regulate, and store that air: the compressor, the governor, the air dryer, and the reservoir tanks. Understanding each component—and knowing how to test and maintain them—is foundational to air brake service and to the ASE T4 (Brakes) credential.
The compressor is engine-driven, typically by a gear on the accessory drive or by a V-belt. Most trucks use a single-cylinder, reciprocating piston compressor, though two-cylinder units appear on larger vehicles. On the compression stroke, the piston moves upward, pressure closes the inlet valve, and air is forced through the discharge valve into the system. On the intake stroke, the piston moves downward, the discharge valve closes, and fresh air is drawn in through the inlet valve.
When the system reaches a set pressure, the governor signals the compressor to unload. Most modern compressors unload by holding the inlet valves open with pressurized air from the governor, so the piston moves air back and forth without compressing it. This protects the compressor from over-pressurizing the system and reduces engine load. During the bench demonstration, locate the unloading port—it is the small fitting on the valve plate cover where governor signal pressure arrives.
The governor is the pressure-sensing switch of the system. It monitors system pressure and controls when the compressor loads (builds pressure) and unloads (stops building pressure).
A governor that allows cut-out pressure to exceed specification can overstress hoses, fittings, and valves. A governor that cuts in too late leaves insufficient reserve pressure for brake applications. Both conditions are out-of-spec and require correction before the vehicle returns to service.
Compressors pull in ambient air, which always contains water vapor. As compressed air cools in the lines and tanks, that vapor condenses into liquid water. Water promotes corrosion inside tanks and valves, freezes in cold weather, and degrades brake valve performance.
The air dryer is plumbed immediately downstream of the compressor. It uses a desiccant cartridge (a bed of moisture-absorbing beads) to strip water vapor from the compressed air before it enters the reservoirs. A purge valve at the bottom of the dryer opens each time the governor signals cut-out, blowing accumulated moisture out of the dryer body. Some dryers also have a heater to prevent freeze-up in cold climates.
Inspect the dryer cartridge per the manufacturer's service interval. A saturated cartridge allows wet air to pass through, and you will find excessive moisture in the wet tank—the first reservoir downstream.
The wet tank (supply reservoir) is the first tank to receive air from the dryer. It acts as a primary moisture trap and surge dampener. Any residual water that makes it past the dryer collects here.
Dry tanks (service reservoirs) are downstream of the wet tank and supply the front and rear brake circuits, the park/emergency circuit, and accessories. Because the dryer removes most moisture before the wet tank, dry tanks should contain very little water under normal conditions.
Every reservoir has a drain valve at its lowest point. Federal Motor Carrier Safety Administration (FMCSA) regulations and most fleet policies require daily manual draining when automatic drain valves are not installed. Draining removes accumulated water and oil contamination before it can damage system components.
PPE: Wear safety glasses at all times during air brake work. Gloves protect hands from sharp edges on disassembled components. Never stand directly in front of a drain valve opening—discharge can carry debris at high velocity.
Depressurize before disassembly: Before removing any fitting, valve, or tank plug, verify system pressure is at zero on a calibrated gauge. Follow your shop's lockout/tagout procedure if the vehicle must be rendered inoperative during service.
Chock the wheels: On the training trailer, always chock wheels before working around brake components, even with the park brake applied.
Gauge accuracy: Use only a calibrated test gauge in the specified range (0–200 psi for most air brake work). A gauge that reads incorrectly will produce false pass results on governor tests.
1. Build system pressure to governor cut-out (confirmed on the dash gauge).
2. Shut down the engine.
3. Put on safety glasses and gloves.
4. Locate each reservoir drain valve—wet tank first, then rear dry tank, then front dry tank, then any auxiliary reservoirs.
5. Open each drain valve fully. Note the color and volume of discharge: clear/dry is acceptable; milky, oily, or a large volume of water indicates a maintenance problem.
6. Record findings on the shop form before closing valves.
7. Close all drain valves and rebuild system pressure; verify no air loss at the drain valves when closed.
1. Connect the calibrated 0–200 psi test gauge to the designated governor test port (or a downstream Schrader fitting if the instructor specifies).
2. Start the engine and observe the gauge as the compressor builds pressure. Note the pressure at which the gauge stops rising—this is cut-out.
3. Make repeated moderate brake applications to draw down system pressure while watching the gauge. Note the pressure at which the gauge begins rising again—this is cut-in.
4. Record both readings on the shop form and compare to the specification range for the training vehicle.
5. Flag any reading outside specification and document the finding.
Mastering these fundamentals prepares you for FMCSA pre-trip inspection requirements, ASE T4 exam content, and the day-to-day responsibilities of a commercial vehicle technician.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →