Objective. Students will mount and align a proximity card reader, an electric strike and a magnetic lock at a practice door station, wire each device to a controller, and verify correct mechanical operation of the door hardware before powering the system.
This lesson, its worked examples and its practice questions has not yet been verified by a credentialed professional in the field or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
Access control works only when the physical hardware is installed correctly. A credential reader that is wired backward, a magnetic lock with a misaligned armature, or a door position switch mounted on the wrong surface can each defeat the entire system. This lesson teaches you to mount, wire, and verify three core devices — a proximity card reader, an electric strike or magnetic lock, and a door position switch — before any power is applied.
Before you pick up a drill, put on safety glasses and cut-resistant gloves. These stay on throughout all drilling, panel work, and wire-termination tasks. When working near door frames and hinges, keep fingers clear of pinch points. If the practice door is connected to any live circuit from a previous exercise, verify the controller is de-energized and the power supply is unplugged before touching terminals. Label the power supply with a caution tag so no one else energizes it while you are working — this is the lockout/tagout principle applied to low-voltage systems. Low-voltage does not mean zero risk: a short across a 12 V, high-current power supply can produce a damaging arc and damage components.
Proximity card readers must be usable by all people, including wheelchair users. ANSI/BHMA accessibility guidelines place the credential-presentation area of a reader at approximately 34 to 48 inches above the finished floor (AFF). The practical target most installers use is 42 inches AFF to the center of the reader face, which falls comfortably within that range and matches the height used for door hardware under accessibility standards.
Use the manufacturer's mounting template — every commercial reader ships with one. Tape it to the wall or door jamb, confirm the center height with a tape measure, mark hole locations with a pencil, and then use an awl or a small drill bit to start pilot holes. On hollow-core practice panels, a standard drywall bit works; on metal backboxes, use a metal-rated bit and cutting fluid. Drive all fasteners firmly but do not overtighten; a torque screwdriver set to the value in the installation sheet prevents cracking the reader housing. Route the reader's pigtail cable or conduit stub through the knockout before seating the reader.
An electric strike replaces the fixed strike plate in a door frame. When the strike is energized (or de-energized, depending on fail mode), its keeper pivots to allow a latch bolt or deadlatch to pass. Installing one requires that the strike body fits the cutout in the frame — ANSI-standard cutouts have defined dimensions so most strikes are interchangeable with the correct faceplate. After seating the strike body, check the door gap with a feeler gauge; the gap between the door edge and the frame face should match the manufacturer's specification, typically 1/8 inch or the value stamped on the frame. Too large a gap prevents the latch from seating; too small a gap causes binding.
Electric strikes can be wired fail-safe (power to lock, loss of power = unlocked) or fail-secure (power to unlock, loss of power = locked). Life-safety codes generally require egress doors to be fail-safe so occupants can exit during a power failure. Confirm the fail mode requirement with local building and fire codes before wiring.
A magnetic lock (magloc) mounts on the door header and holds a steel armature plate attached to the door. When energized, the electromagnet develops holding force — commonly rated at 600 lb for single-door applications. Unlike an electric strike, a magloc has no moving parts, which makes it reliable but also means there is no mechanical backup: if power is lost the door opens. This means all maglocs are inherently fail-safe.
Proper armature alignment is critical. Mount the magloc body to the header bracket first, then close the door and allow the armature to self-center against the magnet face. Tighten the armature mounting screws with the armature held flush — misalignment reduces holding force dramatically and can cause nuisance releases. After alignment, verify there is no gap between the magnet face and the armature face when the door is closed; even a 1/32-inch gap can cut holding force by more than half.
A Request-to-Exit (REX) device lets someone leave the secured side without presenting a credential, preventing the lock from registering an alarm when the door opens legitimately from inside. Passive infrared (PIR) REX sensors detect motion on the egress side and signal the controller to release the lock; push-button REX devices do the same with a manual press. Mount PIR REX sensors so the detection zone covers the entire door swing area and does not extend to the public side.
A door position switch (DPS) tells the controller whether the door is physically open or closed, independent of lock state. Surface-mount reed switches are the most common type: one half mounts on the frame, the magnet half mounts on the door, aligned within the gap tolerance stated by the manufacturer (typically 1/2 inch or less). Wire the DPS to the normally-closed (NC) input on the controller; an open door breaks the circuit and the controller logs a door-open event.
Never energize a new installation without completing a structured pre-power checklist. Verify every wire termination is seated and the correct polarity is observed for polarized devices. Confirm door gap measurement is within specification. Check that the armature seats flush on the magloc. Verify REX wiring is connected to the correct controller input. Manually operate the latch or armature to confirm free movement (free-wheeling test). Your instructor must sign the checklist before you plug in the power supply. After energizing, test all four functions: valid credential releases lock, invalid credential is denied, REX releases lock from inside, and DPS shows correct state in software.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →